Marine Main Switchboard PZ Series
Application:
PZ series main distribution board it is suitable for ships, offshore platform, port, wharf, fixed or mobile power station and other fields,
rated voltage of ac AC660V or dc 250 v and the following system, single generator power from 12 kw to 900 kw of power system,
as a control, monitoring, protection of generators and power lighting distribution.
Model:
Main performance index:
Combined structure: landing free-standing installation
Rated voltage: AC380V/440V
Maximum generatrix current: 5000A
Rated frequency: 50/60Hz
Maintenance way: plate front/plate after
IP rating:top IP 22
Into the line cable position at the bottom of the upper or after(optional)
To comply with relevant classification standard
The main base type product sample:
Generator control panel reference size:
Frame current A | Generator current rating | Wide mm | Height mm | Depth mm |
630 | ≤630 | 600 | 1800-2300 | 600-1000 |
630-1250 | ≤1250 | 700 | ||
1250-1600 | ≤1600 | 700 | ||
1600-2000 | ≤2000 | 800 | 2000-2300 | 800-1000 |
2000-2500 | ≤2500 | 800 | ||
2500-3200 | ≤3200 | 800 |
Technology & Parameters:
Rated voltage | AC400/440V | Frame | Molding steel plate or large box frame |
Rated current | Maximum 500A | IP rating | Top IP22 |
Type | Fully enclosed fixed panel floor many ark combination |
Distribution cable entry | Back bottom(upper optional) |
Rated frequency | 50/60Hz | Armrest | Front and back |
Note:
When ordering, please specify the following content:
a. Generator parameters
b. Instrument configuration
c. The main switch type
d. Load switch type
e. Control room space size or panel allows the space is the largest size, provide the coating material and color requirements
f. Power a system diagram
g. Nameplate material, style and "requirements
h. IP rating requirement
i. Classification requirements
j. Maintenance way: plate front/plate after
k. Incoming line way:bottom/ back upper